Reducing the excess energy consumption on higher ventilation flowrates to control the co2 levels of the central air conditioning systems in polluted urban areas by co2 capturing

dc.contributor.authorWijewardane, MA
dc.contributor.authorHerath, HMPD
dc.contributor.authorRanasinghe, RACP
dc.contributor.editorRathnayake, M
dc.contributor.editorAdhikariwatte, V
dc.contributor.editorHemachandra, K
dc.date.accessioned2022-10-31T07:31:53Z
dc.date.available2022-10-31T07:31:53Z
dc.date.issued2022-07
dc.description.abstractControlling the air quality of the indoor environment is extremely important to improve the health and the productivity of the occupants. The air quality is maintained by providing ventilation air following the ASHRAE standards. The ventilation air (outdoor fresh air), usually processes in the Air Handling Unit (AHU) of the Central AC system, and delivers to the occupant zones. However, supplying outdoor air with increased levels of CO 2 will adversely affect for the health and the productivity of the occupants. In this study, it was found that the CO 2 levels in the indoor environments increase with the increased atmospheric CO 2 levels and the recirculation air percentage. When the CO 2 level of the outdoor air is higher, IAQ can only be controlled by supplying more fresh air to the indoor environment. However, it increases the load on the Cooling Coil and eventually, electricity consumption of the chiller increases. Moreover, the higher excess air flowrates of the MVAC systems require larger fans and increased equipment costs. Therefore, it has been suggested that a CO 2 Capturing Device which is suitable for MVAC systems can handle these extreme scenarios and reduce the operating and maintenance cost of the MVAC systems.en_US
dc.identifier.citationWijewardane, M.A., Herath, H. M. P. D., & Ranasinghe, R. A. C. P. (2022). Reducing the excess energy consumption on higher ventilation flowrates to control the CO2 levels of the central air conditioning systems in polluted urban areas by CO2 capturing. In M. Rathnayake, V. Adhikariwattage, & K. Hemachandra (Eds.), Proceedings of Moratuwa Engineering Research Conference 2022. Institution of Electrical and Electronics Engineers. doi: 10.1109/MERCon55799.2022.9906229en_US
dc.identifier.conferenceMoratuwa Engineering Research Conference 2022en_US
dc.identifier.departmentEngineering Research Unit, University of Moratuwaen_US
dc.identifier.doi10.1109/MERCon55799.2022.9906229en_US
dc.identifier.emailanusha@uom.lk
dc.identifier.emaildinukaprabhashana@gmail.com
dc.identifier.emailchathurar@uom.lk
dc.identifier.facultyEngineeringen_US
dc.identifier.placeMoratuwa, Sri Lankaen_US
dc.identifier.proceedingProceedings of Moratuwa Engineering Research Conference 2022en_US
dc.identifier.urihttp://dl.lib.uom.lk/handle/123/19315
dc.identifier.year2022en_US
dc.language.isoenen_US
dc.publisherIEEEen_US
dc.relation.urihttps://ieeexplore.ieee.org/document/9906229en_US
dc.subjectCO2 capturingen_US
dc.subjectIndoor air qualityen_US
dc.subjectCentral air conditioningen_US
dc.subjectAir handling uniten_US
dc.subjectBuildingsen_US
dc.titleReducing the excess energy consumption on higher ventilation flowrates to control the co2 levels of the central air conditioning systems in polluted urban areas by co2 capturingen_US
dc.typeConference-Full-texten_US