The Effect of ventilation on sick building syndrome

dc.contributor.authorKumara, S
dc.contributor.authorRajapaksa, SW
dc.contributor.authorPerera, SAS
dc.contributor.authorJayasinghe, C
dc.date.accessioned2016-08-10T12:15:17Z
dc.date.available2016-08-10T12:15:17Z
dc.date.issued2016-08-10
dc.description.abstractIt is well known that adverse health conditions could develop due to outdoor air pollutants, such as, C02, CO, S02, NO,, PM (particulate matter), VOC (Volatile Organic Compounds), when people are outdoors, while travelling or working. Since most of the people spend 80-90% of their time indoors, at home or place of work, the presence of these air pollutants could adversely their health while indoors, as well. Hence, minimizing the presence of air pollutants, by taking appropriate measures, such as, ventilation and air conditioning are important to ensure that a healthy atmosphere prevails indoors. In a work place, where a large number of people work within a confined space, C02 produced due to human respiration gets accumulated in the air, unless there is good ventilation. Long exposure to higher C02 concentrations can cause human discomfort and ill health. The C02 concentration, if measured, can be a direct indication of the efficiency of the ventilation system of the building. This paper presents a detailed study on how building planning aspects can affect the indoor environment of a building. The main factor considered was the CO 2 concentration in relation to the ventilation design of the building. In the study, C02 concentration was measured and related to the ventilation design of the space in both free running and air conditioned buildings. The main findings of the study are as follows. a) Planning aspects of building were found to be very important in minimizing the bad effects of air pollutants. b) Provision of openings, based on external wind directions and orientation of the building were important, to dilute and remove high internal air pollutant concentrations by natural air currents. c) Provision of opehings in excess of what is provided in the building regulations was found to improve the ventilation system in a free running building. d) The efficient operation of the natural ventilation system was as important as the ventilation design.en_US
dc.identifier.conferenceInternational Conference on Structural Engineering, Construction and Management (ICSECM - 2011)en_US
dc.identifier.departmentDepartment of Chemical and Process Engineeringen_US
dc.identifier.facultyEngineeringen_US
dc.identifier.placeKandyen_US
dc.identifier.urihttp://dl.lib.mrt.ac.lk/handle/123/11857
dc.identifier.year2011en_US
dc.language.isoenen_US
dc.subjectSick Building, Indoor Air, Ventilationen_US
dc.titleThe Effect of ventilation on sick building syndromeen_US
dc.typeConference-Abstracten_US

Files