Harmonic current compensator

dc.contributor.authorAttanayaka, TL
dc.contributor.authorBandara, PM
dc.contributor.authorBambarawana, IS
dc.contributor.authorBanukobhan, N
dc.contributor.authorKarunadasa, JP
dc.date.accessioned2013-10-21T02:12:48Z
dc.date.available2013-10-21T02:12:48Z
dc.date.issued2010
dc.description.abstractThis paper presents the design and implementation of a Harmonic Current Compensator. Sources of harmonics, harmonic distortion, detrimental effects of harmonics and harmonic elimination methods are considered. Paper describes the operating concept and the system design of the compensator I he compensator mainly consists of two units: the control unit and the full bridge inverter unit. Hysteresis current control is used in the control unit which includes current sensors. 501Iz filler, low pass filter and hysteresis comparator units. Full bridge inverter unit consists H-Bridge, full wave rectifier and current injector. Harmonic current compensator shapes up the input current as sinusoidal irrespective of the shape of load current and it injects harmonic currents adaptively.
dc.identifier.conferenceResearch for Industry
dc.identifier.pgnospp. 151-153
dc.identifier.placeFaculty of Engineering, University of Moratuwa
dc.identifier.proceeding16th Annual symposium on Research and Industry
dc.identifier.urihttp://dl.lib.mrt.ac.lk/handle/123/8218
dc.identifier.year2010
dc.languageen
dc.titleHarmonic current compensator
dc.typeConference-Extended-Abstract