Estimation of voltage unbalance attenuation caused by three-phase induction motors: An extension to distribution system state estimation

dc.contributor.authorKahingala, TD
dc.contributor.authorPerera, S
dc.contributor.authorJayatunga, U
dc.contributor.authorAgalgaonkar
dc.date.accessioned2023-04-18T05:58:23Z
dc.date.available2023-04-18T05:58:23Z
dc.date.issued2019
dc.description.abstractWith the increased interest in controlling and managing voltage unbalance (VU), network operators are now increasingly being motivated to obtain the state of their networks with greater details. Distribution system state estimation (DSSE) is a prominent tool which enables network operators to estimate the level, location and related impacts of VU. DSSE techniques developed to date which use the polynomial or exponential load models are deficient in recognising VU attenuation associated with three-phase induction motors (IMs) that are directly connected to the AC network. Adoption of adequate three-phase models of IMs, that are used in full unbalanced load flow, into the existing DSSE techniques is not feasible due to several factors including requirement of extensive data, additional computational efforts and major constraints related to incorporating the necessary modifications. As a solution, this paper proposes a novel formulation for post processing the results of current DSSE techniques to reflect the aforementioned behaviour of IMs. Simulations are carried out using the IEEE 13 bus distribution network, for a range of scenarios to verify the developed methodology. The work presented in relation to VU attenuation in interconnected networks also complements the existing treatise in IEC documentation which only deals with radial networks.en_US
dc.identifier.citationKahingala, T. D., Perera, S., Jayatunga, U., Agalgaonkar, A. P., & Ciufo, P. (2019). Estimation of voltage unbalance attenuation caused by three-phase induction motors: An extension to distribution system state estimation. IEEE Transactions on Power Delivery, 34(5), 1853–1864. https://doi.org/10.1109/TPWRD.2019.2904505en_US
dc.identifier.databaseIEEE Xploreen_US
dc.identifier.doi10.1109/TPWRD.2019.2904505en_US
dc.identifier.issn0885-8977en_US
dc.identifier.issue5en_US
dc.identifier.journalIEEE Transactions on Power Deliveryen_US
dc.identifier.pgnos1853 - 1864en_US
dc.identifier.urihttp://dl.lib.uom.lk/handle/123/20875
dc.identifier.volume34en_US
dc.identifier.year2019en_US
dc.language.isoenen_US
dc.publisherIEEEen_US
dc.titleEstimation of voltage unbalance attenuation caused by three-phase induction motors: An extension to distribution system state estimationen_US
dc.typeArticle-Abstracten_US

Files