Endurance of insulated CFRP strengthened concrete slab subjected to fire

dc.contributor.authorRanasinghe, RATM
dc.contributor.authorJinadasa, DVLR
dc.contributor.authorSrilal, HPS
dc.contributor.authorGamage, JCPH
dc.date.accessioned2013-12-05T19:03:29Z
dc.date.available2013-12-05T19:03:29Z
dc.date.issued2013-12-06
dc.description.abstractCarbon Fiber reinforced polymer (CFRP) composites are recently becoming an efficacious solution in rehabilitation and strengthening work for deteriorated reinforced concrete structures, because of their superior properties. It is important to maintain a sound interaction between CFRP and concrete for transferring stresses between concrete substrate and the CFRP sheet or plate. However, the epoxy adhesive used to create the bond is very sensitive to the temperature and mechanical properties deteriorate rapidly with exposure to the elevated temperature. The CFRP sheet or plate itself cannot provide sufficient insulation to the composite system. Therefore, application of a suitable insulation onto the CFRP sheet is important especially in the application of buildings. Initially, a numerical model was developed to determine the behaviour of an insulated CFRP strengthened concrete block. The model predicted results were well agreed with the test results. Then the model was further developed to understand the behaviour of a CFRP strengthened concrete slab subjected to fire. Parametric studies were carried out to determine the fire resistance levels of the composite slab with the conductivity and the thickness of insulation.en_US
dc.identifier.conferenceInternational Conference on Structural Engineering Construction and Managementen_US
dc.identifier.departmentDepartment of Civil Engineeringen_US
dc.identifier.facultyEngineeringen_US
dc.identifier.placeKandyen_US
dc.identifier.urihttp://dl.lib.mrt.ac.lk/handle/123/9533
dc.identifier.year2011en_US
dc.language.isoenen_US
dc.subjectCFRPen_US
dc.subjectConcreteen_US
dc.subjectInsulationen_US
dc.subjectFireen_US
dc.subjectFinite element modelingen_US
dc.titleEndurance of insulated CFRP strengthened concrete slab subjected to fireen_US
dc.typeConference-Full-texten_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
SEC-11-164.pdf
Size:
596.56 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: