Performance of severely damaged reinforced concrete flat slab-column connections strengthened with carbon fiber reinforced polymer

dc.contributor.authorSilva, MAL
dc.contributor.authorDedigamuwa, KV
dc.contributor.authorGamage, JCPH
dc.date.accessioned2023-05-22T05:39:52Z
dc.date.available2023-05-22T05:39:52Z
dc.date.issued2021
dc.description.abstractThe punching shear failure of a slab‐column connection is a sudden catastrophic failure. The majority of studies have been focused on the strengthening aspects of non‐cracked slab‐column connections. However, the attention given to the retrofitting of heavily damaged slab‐column connections is comparatively less. Therefore, it is crucial to investigate the suitable damage repairing methods as well as post‐strengthening methods to enhance performance of damaged slab‐column connections. In this study, a total of twenty‐six heavily damaged medium‐scale flat slab‐column connections were repaired using an in‐situ chip concrete mixture. Then the damage repaired specimens were retrofitted using alternative arrangements of Carbon Fiber Reinforced Polymer (CFRP) in such a way to investigate the effects of sensitivity of bond parameters on punching shear performance. The punching shear capacity enhancements observed from retrofitted connections were in the range between 20% and 90%.en_US
dc.identifier.citationSilva, M. A. L., Dedigamuwa, K. V., & Gamage, J. C. P. H. (2021). Performance of severely damaged reinforced concrete flat slab-column connections strengthened with Carbon Fiber Reinforced Polymer. Composite Structures, 255, 112963. https://doi.org/10.1016/j.compstruct.2020.112963en_US
dc.identifier.databaseScienceDirecten_US
dc.identifier.doihttps://doi.org/10.1002/int.22471en_US
dc.identifier.emailanulaksilva@gmail.comen_US
dc.identifier.emailkasun.dv90@gmail.comen_US
dc.identifier.emailkgamage@uom.lken_US
dc.identifier.issn0263-8223en_US
dc.identifier.journalComposite Structuresen_US
dc.identifier.pgnos112963en_US
dc.identifier.urihttp://dl.lib.uom.lk/handle/123/21057
dc.identifier.volume255en_US
dc.identifier.year2021en_US
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.subjectCFRPen_US
dc.subjectExternal strengtheningen_US
dc.subjectHeavily damaged slab‐columnen_US
dc.subjectPunching shearen_US
dc.subjectRetrofittingen_US
dc.titlePerformance of severely damaged reinforced concrete flat slab-column connections strengthened with carbon fiber reinforced polymeren_US
dc.typeArticle-Full-texten_US

Files