Efficiency improvement of solar photovoltaic thermal systems by experimental and numerical analysis

dc.contributor.authorKarunasena, UTRK
dc.contributor.authorKarunarathna, MAP
dc.contributor.authorKumara, DGAS
dc.contributor.authorManthilake, MMID
dc.contributor.authorPunchihewa, HKG
dc.contributor.editorEdussooriya, C
dc.contributor.editorWeeraddana, CUS
dc.contributor.editorAbeysooriya, RP
dc.date.accessioned2022-08-08T03:36:45Z
dc.date.available2022-08-08T03:36:45Z
dc.date.issued2020-07
dc.description.abstractThe power output of solar panels shows an invene relation with increasing its operating temperature and that affects largely for countries tike Sri Lanka, wbich are situated near the equator. Possible cooling techniques, which are aligned with the Sri Lankan context, were studied by referring to past research and available systems. Rear side forced water-cooling with a thermal coUector wbich is known as the hybrid system was identified as the most feasible technique by considering economic and environmental facton. The theoretical model was developed to estimate the design parameters of the thermal collector and cooling performance. The number of ten thermal collector design configurations were modeled and analyzed the cooting performance using ANSYS fluent simulations. The best design configuration was identified based on heat transfer and manofacturiog capability. A prototype of the selected design was manufactured to investigate the cooling performance experimentally. The experimental setup was developed using two 100 Watts solar panels and a smaU scale cooUng tower.Both power and panel temperature variation were analyzed both numerically and experimentally. The numerical model was vatidated using experimental results and design parameters were optimized as it gives a better cooling performance. Both numerical and experimental analysis shows that integrating a rear side cooling system would increase both electrical and thermal efficiency by 65%. The electrical efficiency improvement is 2.5 % and electrical power generation is increased by 28% compared to the panel without cooling. Considering the cost benefits and the environmental conditions of Sri Lanka, using a solar PV hybrid system is a feasible option to enhance both electrical and thermal gains.en_US
dc.identifier.citation*******en_US
dc.identifier.conferenceMoratuwa Engineering Research Conference 2020en_US
dc.identifier.departmentEngineering Research Unit, University of Moratuwaen_US
dc.identifier.doi10.1109/MERCon50084.2020.9185279en_US
dc.identifier.emailthushanrasika25@gmail.comen_US
dc.identifier.emailpushpamalkanmarathua@gmail.comen_US
dc.identifier.emailamiladsandun@gmail.comen_US
dc.identifier.emailimanthilake@uom.lken_US
dc.identifier.emailhpunchihewa@uom.lken_US
dc.identifier.facultyEngineeringen_US
dc.identifier.pgnospp. 488-493en_US
dc.identifier.placeMoratuwa, Sri Lankaen_US
dc.identifier.proceedingProceedings of Moratuwa Engineering Research Conference 2020en_US
dc.identifier.urihttp://dl.lib.uom.lk/handle/123/18531
dc.identifier.year2020en_US
dc.language.isoenen_US
dc.publisherIEEEen_US
dc.relation.urihttps://ieeexplore.ieee.org/document/9185279en_US
dc.subjectSolar PV-Therma/ coUectoren_US
dc.subjectCooling Solar PV modulesen_US
dc.subjectPV Conversion ef/iciencyen_US
dc.subjectSolar module temperatureen_US
dc.titleEfficiency improvement of solar photovoltaic thermal systems by experimental and numerical analysisen_US
dc.typeConference-Full-texten_US

Files

Collections