Development of a soft linear actuator to use in wearable assistive exosuits

dc.contributor.advisorChathuranga KVDS
dc.contributor.advisorGopura RARC
dc.contributor.advisorLalitharatne SWHMTD
dc.contributor.authorKulasekera AL
dc.date.accept2023
dc.date.accessioned2023
dc.date.available2023
dc.date.issued2023
dc.description.abstractWearable exosuits require flexible, linearly contractile, and lightweight actuators to provide sufficient force to move the respective limb. This thesis presents the concept, design, fabrication, experimental performance characterization, and numerical modeling of two types of respectively thin and low-profile vacuum-driven, soft, linearly contractile actuators. The proposed soft actuators are made of an inextensible yet flexible thin-skinned pouch supported by a collapsible skeleton that orients the collapse of the actuator in the longitudinal axis upon the evacuation of the air within the pouch. The proposed novel soft, lightweight, contractile actuators are thin (ThinVAc) and lowprofile (LPVAc). Both these actuators are lightweight (ThinVAc: 0.75 g; LPVAc: 14 g), provide high maximum blocked forces (ThinVAc: 5.2 N; LPVAc: 39 N), provide maximum stresses similar to that expected from biological muscles (ThinVAc: 184 kPa; LPVAc: 117 kPa) and have high force-to-weight ratios (ThinVAc: 477; LPVAc: 285). The ThinVAc can combine to create multifilament actuators for force scaling. Combining 15 units of 500 mm ThinVAcs generates a maximum blocked force of 54 N (Max. stress: 62 kPa), 290 times the self-weight. The LPVAc integrates a position sensor based on an inductive sensor allowing closed-loop control with minimal error at 0.25 Hz. Numerical models for the contraction and blocked force of mono- and multifilament actuators allow for predicting their behavior independent of external sensors. The proposed actuators are tested in wearable applications to check their suitability. The ThinVAc is integrated into a knee rehabilitation assist device, and the LPVAc is incorporated into a novel mono-articular sit-to-stand transition (StSt) assist exosuit, helping to reduce muscle activity by 45%. These actuators have the potential to be integrated into a wide range of assistive devices and orthoses, such as knee or ankle braces, exoskeletons, and prosthetics, to provide the necessary support for people with mobility impairments.en_US
dc.identifier.accnoTH5145en_US
dc.identifier.citationKulasekera, A.L.. (2023). Development of a soft linear actuator to use in wearable assistive exosuits [Doctoral dissertation, University of Moratuwa]. Institutional Repository University of Moratuwa. hhttp://dl.lib.uom.lk/handle/123/22105
dc.identifier.degreeDoctor of Philosophyen_US
dc.identifier.departmentDepartment of Mechanical Engineeringen_US
dc.identifier.facultyEngineeringen_US
dc.identifier.urihttp://dl.lib.uom.lk/handle/123/22105
dc.language.isoenen_US
dc.subjectLINEAR SOFT ACTUATORSen_US
dc.subjectEXOSUITSen_US
dc.subjectCONTRACTILE VACUUM ACTUATORSen_US
dc.subjectSOFT ROBOTICSen_US
dc.subjectSOFT SENSORSen_US
dc.subjectMECHANICAL ENGINEERING-Dissertationsen_US
dc.titleDevelopment of a soft linear actuator to use in wearable assistive exosuitsen_US
dc.typeThesis-Full-texten_US

Files