Design and development of a novel oral care simulator for the training of nurses

dc.contributor.authorHerath, B
dc.contributor.authorDewmin, GHS
dc.contributor.authorSukumaran, S
dc.contributor.authorAmarasinghe, YWR
dc.contributor.authorDe Silva, AHTE
dc.contributor.authorMitani, A
dc.contributor.authorWijethunge, D
dc.contributor.authorSampath, WHP
dc.date.accessioned2023-02-22T08:50:14Z
dc.date.available2023-02-22T08:50:14Z
dc.date.issued2020
dc.description.abstractObjective: A Novel Oral Care Simulator was designed and developed to measure and visualise the facial and lingual forces exerted on teeth by the action of tooth brushing, considering the irregular geometry and structural composition of human dentition and the emulation of the realistic biomechanical deflection of the teeth. Method: FEA simulations were carried out on a central incisor under facial loading and an appropriate force sensing mechanism was designed. An anatomically accurate mandibular jaw and 16 teeth were 3D printed, on which 16 force sensing structures were embedded. The signals from the sensors were amplified using a multichannel signal amplifier built using instrumentation amplifiers which were then visualised through a GUI. Results: The developed simulator is capable of indicating the magnitude of a force upto 15 N exerted on to the facial and lingual surfaces of teeth at a frequency of 60 Hz and above and it is capable of alerting the user if the force exceeds a pre-specified threshold. Conclusion: The designed force sensing mechanism considers the irregular geometry and structural composition of human dentition in measuring the facial and lingual forces. It provides a reliable feedback by indicating the force and emulating the realistic biomechanical deflection of teeth. Significance: Nurses who care for the disabled, elderly and sick have explicitly stated the requirement for a simulator to train themselves on brushing the teeth of their subjects as their incorrect technique can cause longterm dental damage, for which a device has not been developed to date.en_US
dc.identifier.citationHerath, B., Dewmin, G. H. S., Sukumaran, S., Amarasinghe, Y. W. R., De Silva, A. H. T. E., Mitani, A., Wijethunge, D., & Sampath, W. H. P. (2020). Design and Development of a Novel Oral Care Simulator for the Training of Nurses. IEEE Transactions on Biomedical Engineering, 67(5), 1314–1320. https://doi.org/10.1109/TBME.2019.2936050en_US
dc.identifier.databaseIEE Xploreen_US
dc.identifier.doi10.1109/TBME.2019.2936050en_US
dc.identifier.issn1558-2531en_US
dc.identifier.issue5en_US
dc.identifier.journalIEEE Transactions on Biomedical Engineeringen_US
dc.identifier.pgnos1314-1320en_US
dc.identifier.urihttp://dl.lib.uom.lk/handle/123/20594
dc.identifier.volume67en_US
dc.identifier.year2020en_US
dc.language.isoen_USen_US
dc.publisherIEEen_US
dc.subjectFEAen_US
dc.subjectForce Sensoren_US
dc.subjectHuman Dentitionen_US
dc.subjectOral Care Simulatoren_US
dc.titleDesign and development of a novel oral care simulator for the training of nursesen_US
dc.typeArticle-Full-texten_US

Files