dc.description.abstractDiabetes needs regular blood glucose monitoring to control it. Invasive blood glucose measuring is the current gold standard. It causes discomfort for the patient and sometimes even infections. Researchers around the world have reported different techniques to measure blood glucose levels non-invasively, but a universally acceptable method with required accuracy is not yet available. We proposed a novel approach to measure blood glucose level non-invasively using a hybrid technique combining Near InfraRed (NIR) absorption and bio-impedance measurements. We tested the methods individually first. Then Artificial Neural Network (ANN) and least squares regression were used to integrate the two methods. The combined methods showed better accuracy compared to the individual measurements. The hybrid technique developed using the linear regression models showed a superior outcome with 90% and 10% of the data points in the regions A and B of the Clarke error grid, which are considered acceptable.en_US
dc.identifier.citationN. D. Nanayakkara, S. C. Munasingha and G. P. Ruwanpathirana, "Non-Invasive Blood Glucose Monitoring using a Hybrid Technique," 2018 Moratuwa Engineering Research Conference (MERCon), 2018, pp. 7-12, doi: 10.1109/MERCon.2018.8421885.en_US
dc.identifier.conference2018 Moratuwa Engineering Research Conference (MERCon)en_US
dc.identifier.departmentEngineering Research Unit, University of Moratuwaen_US
dc.identifier.doi10.1109/MERCon.2018.8421885en_US
dc.identifier.emailnuwan@uom.lken_US
dc.identifier.emailshashika.chamod11@gmail.comen_US
dc.identifier.emailruwan.gihan@gmail.comen_US
dc.identifier.facultyEngineeringen_US
dc.identifier.pgnospp. 7-12en_US
dc.identifier.placeMoratuwa, Sri Lankaen_US
dc.identifier.proceedingProceedings of 2018 Moratuwa Engineering Research Conference (MERCon)en_US
dc.identifier.urihttp://dl.lib.uom.lk/handle/123/18863
dc.identifier.year2018en_US
dc.language.isoenen_US
dc.publisherIEEEen_US
dc.relation.urihttps://ieeexplore.ieee.org/document/8421885en_US
dc.subjectnon-invasive blood glucose measuring (nibgm)en_US
dc.subjectnear-infrared (NIR) absorptionen_US
dc.subjectbio-impedanceen_US
dc.subjectdiabetic mellitusen_US
dc.titleNon-invasive blood glucose monitoring using a hybrid techniqueen_US