Browsing by Author "Senanayake, A"
Now showing 1 - 3 of 3
- Results Per Page
- Sort Options
- item:Evaluation of cover soil properties of solid waste dumpsites in Colombo District, Sri LankaHarshani, HMD; Nawagamuwa, UP; Senanayake, A;Landfill cover soils have to serve multiple purposes such as operational safety, environmental protection, recultivation and integration of the sites into the landscape. Cover soil properties must therefore be defined with respect to the thickness, bulk density, air permeability and the available field capacity. The primary objective of this study is to examine the cover soil properties of three selected landfill sites (dumpsites) in Sri Lanka in order to propose suitable cover soil properties for similar applications in future dumpsites. Soil samples were obtained from three landfill sites in and around the city of Colombo. Laboratory tests to establish compaction characteristics, air permeability, particle size distribution and Atterberg limits were performed to assess the suitability as landfill cover soils. The study showed that landfill covers with well graded soils comply with the dry density and air permeability values, as per the guidelines. In the absence of proper gas venting facilities, it is essential to study the permeability properties of the cover soil. All three landfill sites tested need to be retrofitted with leachate and gas collecting systems that meet the standards stipulated in the guidelines.
- item: Conference-AbstractRole of 3d-finite element modelling in the analysis of soil-structure interaction problems(Department of Civil Engineering, 2011-07) Senanayake, A; Jayawickrama, PW; Lawson, WD; Pasindu, HREngineering design and analysis often rely on simplified models. These models are convenient and practical for use in routine applications. However, they have many inherent limitations. Most significant among these limitations are their inability to model the following: (a) the true non-linear, material behavior, (b) actual construction sequence, (c) dynamic effects of moving traffic loads, (d) the actual 3- dimensional configuration of the structure and (e) 3 dimensional the loading pattern. As a rule, these simplified analysis methods rely on assumptions that are conservative. But sometimes the degree of conservatism can be unacceptably high. This paper describes a research study that used a 3D FEM to find an explanation for apparent disagreement between simplified model predictions for the load rating of highway culverts and results from field inspections of these culverts. When highway reconstruction projects involve widening or change in elevation of roadways, highway agencies are required to reevaluate existing culverts using AASHTO culvert load rating procedures to verify their structural adequacy. Such reanalysis often indicate that the existing culverts are structurally deficient and therefore must be replaced or retrofitted. However, inspections conducted during replacement of the old culverts show that these structures are in sound structural condition and have no significant distresses. This implied that the existing load rating methods were too conservative and new guidelines were put in place in 2009 based on research conducted by the Texas Tech University. One key aspect of this research was to understand how soil-structure interaction affects culvert performance and how these effects may be included in the load rating procedure. The revised guide suggested the use finite element (FE) models of different levels of sophistication to help analysts in load rating. Furthermore, the guide states although 2D FE models with simplifying assumptions are acceptable for load rating purposes, they are not capable of predicting the culvert performance completely and recommends the use of 3D models for further research. Hence, this study employed a 3D FE model which simulated the behaviour of the culvert, the surrounding soil and the pavement as one whole unit under the exact 3D wheel load configurations applied in the field testing in an attempt to predict culvert behaviour more accurately. The FE model was built using ANSYS Workbench and allowed for project-specific input values, soil-structure interaction and was equipped with parametric analysis capability. The 3D FE model was then fed with site specific input parameters determined from detailed site characterization tests. As expected the 3D FE model was able to predict the deformations in the culverts far more accurately than the 2D models. The model was then used to carry out a sensitivity analysis to determine how parameters such as soil and pavement stiffness influenced the structural performance of the culvert.
- item:Utilization of waste copper slag as a substitute for sand in vertical sand drains and sand pile(2015-05-28) Nawagamuwa, UP; Senanayake, A; Rathnaweera, TVertical sand drains are used as a method of expediting consolidation for ground improvement projects. Unfortunately, the installation of vertical sand drains have become less economically viable due to the high costs and limited availability of good quality sand. Particle size distribution analyses done on samples of waste copper slag obtained from the Colombo dockyard revealed that its gradation was similar to that of sand, which meant that waste copper slag could potentially be used as a substitute for sand, provided that it did not adversely affect the hydraulic conductivity of the resulting mixture. In this study, constant head permeability tests were done on "sand-copper slag" mixes of varying proportions and it was shown that up to 50% copper slag by weight could be added to sand without an appreciable loss in permeability. The performance of sand piles is dependent on strength and settlement characteristics of the sand. Hence, consolidation tests and direct shear tests were also carried out on the "sand-copper slag" mixes to explore how the mechanical properties of sand were affected by the copper slag.